VAULTED CEILINGS

PROTECTION TO FIRE RETROFIT OF EXISTING SLABS

 

Reference standard: Eurocode EN 1996-1-2 appendix C and DCPREV Regulatory Bulletin 4683 dated 05/04/2013
FIRE RESISTANCE: R EI
Exposure to fire: intrados
Height and stratigraphy of slab: solid brick of 125
Protective system: Amotherm Brick WSB – transparent, intumescent, mono-component cycle
Consumption: 1.2 kg/m2
Technical reference document: Test report no. 397649
Maximum allowable load: to be verified in the analytical stage of project
Surface preparation: Amotherm Primer WB

 
 